Caution – HT instruments SOLAR300N User Manual

Page 165

Advertising
background image

SOLAR300 - SOLAR300N

EN - 163

7.7. RECORDING IN A PV-1 SYSTEM WITH REMOTE UNIT SOLAR-02

CAUTION

 The maximum voltage between inputs D1, D2, A1, A2 and A3 is 1000V /

CAT IV 600V to earth. Do not measure voltages exceeding the limits
indicated in this manual. If these voltage limit values are exceeded, the user
may be exposed to electrical shocks and the instrument could get damaged

 Where possible, disconnect the connecting points of the instrument, before

connecting it, by means of disconnecting switches S1 and S2

 If there is NO interest in recording the data relevant to the environmental

quantities (temperature and irradiation), it is NOT necessary to use and
connect the unit SOLAR-02 to main unit

Fig. 249: Connecting the instrument in a PV-1 system with SOLAR-02

1. Check and, if necessary, change the basic settings of the instrument relative to PV-1

configuration (see § 5.3.1, 5.3.2 and 5.3.3). Also check that the parameters of the
photovoltaic system considered correspond to the set values. For setting of
pyranometer or reference cell HT304 sensitivity please refer to the user manual of
SOLAR-02.

2. Use the remote unit SOLAR-02 under independent mode to perform a possible preliminary

measurement of irradiance.

3. Connect inputs D1 and D2 to the positive and negative string output pole respectively.

Connect inputs A1 and A2 to the phase and neutral conductors, respecting the colors
as shown in Fig. 249

CAUTION

BEFORE CONNECT DC CLAMP ON CONDUCTOR

Turn on the clamp, select the correct range and press the ZERO key to the
DC clamp in order to eliminate possible residual magnetizations in the
clamp (values of current up to 0.02A are acceptable). Connect the output
of the clamp to the IDC input of the instrument


4. Connect the DC current clamp to the positive string output conductor by respecting

the direction of the arrow on the clamp itself as indicated in Fig. 249. Check the
status of internal batteries of the DC clamp after the connection to the
installation