HT instruments SOLAR300N User Manual

Page 63

Advertising
background image

SOLAR300 - SOLAR300N

EN - 61

5.4.1.9. Item General Parameters for use with MPP300 unit
After setting MPP300 as remote unit (see § 5.3.3) the instrument will display a selection
tree, in which it will be possible to change only the “comment” fields and the value of the
integration period.

Fig. 113: Section of General Parameters: no selection

The list of the recorded quantities cannot be changed and is only related to the number of
DC inputs set (MPPT) and to the type of electric system at the inverter output (single-
phase or three-phase).

PV systems with MPP300

GENERAL MENU SECTION

PARAMETER

SETTING

Recording configuration

Comments (empty)

Start Manu

Stop Manu

Integration period

5 sec .. 60min

General Parameters

MPP300-1

system

VDCx, IDCx, PDCx,

Hz, V1N, I1, P1, Ea1

MPP300-3

system

VDCx, IDCx, PDCx,PDCtot

Hz, V1N,V2N,V3N,V12,V23,V31,

I1, I2, I3, P1, P2, P3,Ptot, Ea1,

Ea2, Ea2, Eatot

SOLAR-02

Irradiation, Celle Temperature, Environmental

Temperature

x = 1,2,3 according to the number of DC inputs (MPPT) set.

Press the SAVE or ENTER keys (or the smart icon

) to save each selected setting. In

this condition, the instrument shows a window to confirm the saving. In this window,
confirm by pressing “Ok”. Once the operation has been completed, the instrument goes
back to the general menu screen.
To quit the modifications made or to exit without saving, press the ESC key (or the smart
icon ).