3 stabilizer valve, Stabilizer valve – JLG G12-55A AccuPlace Service Manual User Manual

Page 106

Advertising
background image

Hydraulic System

8.16

G10-55A & G12-55A AccuPlace

4. Uncap and connect the previously labeled hydraulic

hoses to their appropriate locations.

5. Connect the battery negative (-) cable to the battery

negative (-) terminal.

6. Before starting the machine, check fluid level of the

hydraulic fluid reservoir and if necessary fill to full
mark with Mobilfluid 424

®

(ISO 46).

7. Start the machine and run at low idle for about one

minute. Test the functions of the ISP valve.

8. Inspect for leaks and check level of hydraulic fluid in

reservoir. Add hydraulic fluid if needed. Shut the
engine OFF.

9. Close and secure the engine cover.

8.8.3

Stabilizer Valve

a. Stabilizer Valve Removal

1. Park the machine on a firm, level surface, level the

machine, fully retract the boom, lower the boom,
place the transmission control lever in (N) NEUTRAL,
engage the park brake and shut the engine OFF.

2. Place a Do Not Operate Tag on both the ignition key

switch and the steering wheel, stating that the
machine should not be operated.

3. Open the engine cover. Allow the system fluids to

cool.

4. Disconnect the battery negative (-) cable from the

battery negative (-) terminal.

5. Thoroughly clean the valve and surrounding area,

including all hoses and fittings before proceeding.

6. Remove the valve protective cover from the machine

frame.

7. Label, disconnect and cap the hydraulic hoses

attached to the stabilizer valve (5). Cap all fittings to
prevent dirt & debris from entering the hydraulic
system.

8. Label and disconnect the electrical connectors from

the stabilizer valve.

9. Remove the hardware securing the stabilizer valve

to the machine frame.

b. Stabilizer Valve Installation

1. Install the stabilizer valve to the machine frame with

the previously used hardware.

2. Connect the previously labeled electrical connectors

to the stabilizer valve.

3. Uncap and connect the previously labeled hydraulic

hoses to their appropriate locations.

4. Connect the battery negative (-) cable to the battery

negative (-) terminal.

5. Before starting the machine, check fluid level of the

hydraulic fluid reservoir and if necessary fill to full
mark with Mobilfluid 424

®

(ISO 46).

6. Start the machine and run at low idle for about one

minute. Test the functions of the stabilizer valve.

7. Inspect for leaks and check level of hydraulic fluid in

reservoir. Add hydraulic fluid if needed. Shut the
engine OFF.

8. Close and secure the engine cover.

c. Stabilizer Valve Adjustment

If slow motion is experienced on one of the stabilizers/
outriggers after one of the two stabilizers/outriggers hits
end of stroke, use the following procedure to adjust the
stabilizer valve:

1. Extend one stabilizer/outrigger to end of stroke.

2. Measure the pressure at the valve LS port (7).

3. Adjust the load sense relief valve screw (6) until the

measured pressure is 325 psi (22 bar) below system
pressure (nominally 3300 psi (228 bar)) as read via
the analyzer under DIAGNOSTICS/ISP.

MAP0240

5

MAP0730

6

7

Advertising