JLG G12-55A AccuPlace Service Manual User Manual

Page 163

Advertising
background image

9.45

G10-55A & G12-55A AccuPlace

Electrical System

Fork Up End of Stroke Threshold

“FORK UP SOFT ZN”

23.0 DEG

0.0 -50.0 DEG

Fork Down End of Stroke Threshold

“FORK DN SOFT ZN”

-115.0 DEG

-125.0 - (-90.0) DEG

Fork Tilt Flow Priority

“FORK FLOW PRIOR”

False

True/False

Auxiliary Hydraulics Flow Priority

“AUX FLOW PRIOR”

False

True/False

Lift Down Derating When Telescoped Out

“LIFT DN DERATE”

0.5

0.2-0.9

Lift Down Derating When Telescoped Out

Begin Point

“LIFT DN DERATE START”

4.26 FT

(1300mm)

1.64-9.18 FT

(500-2798mm)

Lift Down Engine Speed Dependency

“LIFT DOWN SPEED”

RPM BASED

RPM BASED/NOT

RPM BASED

AccuPlace Vertical Height Limit

“ACCUPLACE MAX HEIGHT”

52.7 FT

44.9-59.9 FT

Allow Difference Between Boom Angle

Readings

“ALLOWED BM ANGLE DIFF”

±8 DEG

±4 to ±10 DEG

Function

Personality

Default Setting

Adjustment Range

Advertising
This manual is related to the following products: