9.74

G10-55A & G12-55A AccuPlace

BATTERY
VOLTAGE LOW

445

UGM measures battery
voltage < 11V for more than
3 seconds (excluding during
engine cranking).

N

Recharge batteries or check for damaged
batteries.

Also, wiring to UGM may be faulty.
Confirm voltage reading with a multimeter
at UGM connector J8.

LIFT VALVE –
VOLTAGE TO
LOW

449

Lift valve controller detects
supply voltage < 9V for 1
second.

Y

Recharge batteries or check for damaged
batteries.

Verify consistent voltage readings at other
control modules via the Analyzer under
Diagnostics/System Power. If the module
is providing an inconsistent reading, check
for faulty wiring to the module using a
multimeter.

LIFT VALVE –
VOLTAGE TOO
HIGH

4410

Lift valve controller detects
supply voltage > 17V for 1
second.

Y

May be due to improper battery charging
or incorrect voltage batteries being used.

Verify consistent voltage readings at other
control modules via the Analyzer under
Diagnostics/System Power. If
inconsistent, check voltage going into
module. If inconsistent with other modules
or reading on Analyzer, module
replacement may be required.

TELESCOPE
VALVE –
VOLTAGE TOO
LOW

4411

Tele valve controller detects
supply voltage < 9V for 1
second.

Y

Recharge batteries or check for damaged
batteries.

Verify consistent voltage readings at other
control modules via the Analyzer under
Diagnostics/System Power. If the module
is providing an inconsistent reading, check
for faulty wiring to the module using a
multimeter.

TELESCOPE
VALVE –
VOLTAGE TOO
HIGH

4412

Tele valve controller detects
supply voltage > 17V for 1
second.

Y

May be due to improper battery charging
or incorrect voltage batteries being used.

Verify consistent voltage readings at other
control modules via the Analyzer under
Diagnostics/System Power. If
inconsistent, check voltage going into
module. If inconsistent with other modules
or reading on Analyzer, module
replacement may be required.