JLG G12-55A AccuPlace Service Manual User Manual

Page 190

Advertising
background image

Electrical System

9.72

G10-55A & G12-55A AccuPlace

CIRCULATION
VALVE – SHORT
TO BATTERY

3337

Feedback voltage on UGM
pin J1-11 indicates STB
fault.

N

Check for continuity through this circuit.

Inspect wiring for physical damage.

With the engine off but controller power
on, and with the circulation valve
disconnected, the open circuit voltage at
the valve connector should be around
8.0V or less. If not, continue tracing the
circuit back toward the cab wall (rear of
boom, cab wall, UGM connectors, etc.)
and making measurements to determine
where the STB exists. Once isolated,
perform continuity check to narrow source
of problem.

CIRCULATION
VALVE – SHORT
TO GROUND

33346 Voltage on UGM pin J1-11

while driving coil indicates
STG condition.

N

Check for coil damage or a shorting
condition in this circuit.

Inspect wiring for physical damage. The
low side of this coil should be within 1ohm
resistance to the negative battery
terminal.

CIRCULATION
VALVE – OPEN
CIRCUIT

33347 Feedback voltage on UGM

pin J1-11 indicates STB
fault.

N

Check for continuity through this circuit.

Inspect wiring for physical damage.

Note: An open circuit voltage of nearly
8.0V exists on this UGM pin for circuit
diagnostic purposes.

REAR
STABILIZER ONE
VALVE – SHORT
TO BATTERY

33348 Feedback voltage on UGM

pin J1-13 indicates STB
fault.

N

Check for continuity through this circuit.

Inspect wiring for physical damage.

With the engine off but controller power
on, and with the valve disconnected, the
open circuit voltage at the valve connector
should be around 8.0V or less. If not,
continue tracing the circuit back toward
UGM, making measurements to
determine where the STB exists. Once
isolated, perform continuity check to
narrow source of problem.

REAR
STABILIZER ONE
VALVE – SHORT
TO GROUND

33349 Voltage on UGM pin J1-13

while driving coil indicates
STG condition.

N

Check for continuity through this circuit.

Inspect wiring for physical damage. The
low side of this coil should be within 1ohm
resistance to the negative battery
terminal.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising