JLG G12-55A AccuPlace Service Manual User Manual

Page 222

Advertising
background image

Electrical System

9.104

G10-55A & G12-55A AccuPlace

FORK POSITION
SENSOR - NOT
DETECTING
CHANGE

8469

Controls determine slow
response to commands. Not
reported if cab joystick not
commanding motion.

Y

If not tracking well calibrate fork sensor.
Refer to Section 9.15.5, “Calibrations.”

BOOM LIFT
OVERSPEED

8470

Controls determine too fast
boom motion for commands.
Not reported if cab joystick
not commanding motion.

Y

Fault generally occurs for an overrunning
load or when the machine is used outside
of its intended operating parameters.

Cycle power to see if fault clears.

If fault still exists after motion is
commanded, check integrity of Boom
Angle sensors.

TELESCOPE
OVERSPEED

8471

Controls determine too fast
Telescope motion for
commands. Not reported if
cab joystick not commanding
motion.

Y

Fault generally occurs for an overrunning
load or when the machine is used outside
of its intended operating parameters.

Cycle power to see if fault clears.

If fault still exists after motion is
commanded, check integrity of Boom
Length sensor.

FORK
OVERSPEED

8472

Controls determine too fast
boom motion for commands.
Not reported if cab joystick
not commanding motion.

Y

Fault generally occurs for an overrunning
load or when the machine is used outside
of its intended operating parameters.

Cycle power to see if fault clears.

If fault still exists after motion is
commanded, check integrity of Fork
Position sensor.

WRONG LIFT
RESPONSE

8414

Controls determine motion
direction opposite the
commanded direction for
more than 1 second. Not
reported if cab joystick not
commanding motion.

Y

Fault may indicate improper electrical or
hydraulic connections after a repair.

Cycle power to see if fault clears.

If fault still exists after motion is
commanded, check connections and
integrity of Boom Angle sensors.

WRONG
TELESCOPE
RESPONSE

8413

Controls determine motion
direction opposite the
commanded direction for
more than 1 second. Not
reported if cab joystick not
commanding motion.

Y

Fault may indicate improper electrical or
hydraulic connections after a repair.

Cycle power to see if fault clears.

If fault still exists after motion is
commanded, check connections and
integrity of Boom Length sensor.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising