Electrical System

9.10

G10-55A & G12-55A AccuPlace

e. UGM Connections

a. UGM Inputs

MAP0540

J3

J4

J2

J1

J8

J12

J7

UGM

Connector/Pin

Description

Description/Purpose

J3-2

Sway Valve Return

Current feedback return for Sway Left and Right Solenoids

J3-6

Right Stabilizer Valve

Return

Current feedback return for Right Up and Down Solenoids

J3-13

Boom Angle Right

Sensor Signal

Analog Input

Signal Range: 0.5 – 4.5V

0.5V = 0°

4.5V = 90°

J3-14

Left Stabilizer Valve

Return

Current feedback return for Left Up and Down Solenoids

J4-6

AccuPlace Mode Fault

Reset Switch

High Sensing

Digital Input

Closed = V

bat

= Request to Reset Fault to

Continue Motion

J4-10

Sway Joystick Out of

Neutral

High Sensing

Digital Input

Closed = V

bat

= Out of Neutral

J4-11

Aux Joystick Out of

Neutral

High Sensing

Digital Input

Closed = V

bat

= Out of Neutral

J4-18

Boom Ride Enable

Switch

Closed = V

bat

= Request for Boom Ride Mode

J4-23

Right Stabilizer Joystick

Out of Neutral

Closed = V

bat

= Out of Neutral

J4-30

Continuous Auxiliary

Hydraulics Switch

Closed = V

bat

= Request for Boom Ride Mode