9.51

G10-55A & G12-55A AccuPlace

Electrical System

RT STAB JOY CMD:

±XXX%

Displays position in percentage for this axis;
positive is lower voltages and negative is higher
voltages.

RT STAB SIGNAL:

X.XV

Provides voltage signal output for joystick.

RT STAB NEUT SW:

NEUTRAL/OUT OF
NEUTRAL

Indicates whether joystick switches designate out-
of-neutral position.

BOOM
COMPONENTS:

BOOM ANGLE LEFT: ±XX.X DEG

Displays boom angle of left-mounted CAN sensor
with negative degrees below horizontal; 90°
means invalid reading.

BOOM ANGLE LEFT: XXXXX COUNTS

Displays raw counts of left-mounted CAN sensor.

BOOM ANGLE RT:

±XX.X DEG

Displays boom angle of right-mounted analog
sensor with negative degrees below horizontal;
90× means invalid reading.

BOOM ANGLE RT:

XXXXX COUNTS

Displays raw counts of right-mounted analog
sensor.

TELE LENGTH:

XXX.X INCHES

Displays total boom length reading; 900” means
invalid reading.

TELE LENGTH:

XXXXX COUNTS

Displays raw counts of boom length sensor.

FORK ANGLE:

±XXX.X DEG

Displays fork angle with negative angles below
horizontal. This calculation uses Attachment F to
relate Fork Angle to Cylinder Length (displayed
only if MTS configured).

FORK LENGTH:

XXXXX.X INCHES

Displays calibrated length in inches of Fork
Length sensor.

FORK LENGTH:

XXXXX COUNTS

Displays raw counts of Fork Length sensor.

ISP BOOM ANGLE:

2

±XXX.X DEG

Displays Boom Angle computed by ISP.

ISP BOOM LENGTH:

2

XXX.X INCHES

Displays Boom Length computed by ISP.

ISP FORK ANGLE:

2

±XXX.X DEG

Displays Boom Angle computed by ISP.

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter

(Displayed on

Analyzer 1

st

Line)

Parameter Value

(Displayed on

Analyzer 2

nd

Line)

Description