9.53

G10-55A & G12-55A AccuPlace

Electrical System

ISP:

ISP SUPPLY PRESS: XXXX.X PSI

System Pressure at Pump Manifold (PS).

ISP LS PRESS:

1

XXXX.X PSI

Load Sense Pressure at Pump Manifold (PCLS).

ISP SUPPLY TEMP:

±XXXDEG C

Hydraulic Supply Oil Temperature reported at
Pump Manifold.

ISP LS TEMP:

1

±XXXDEG C

Hydraulic LS Oil Temperature reported at Pump
Manifold.

PUMP MANFLD CMD:

XXXXmA

Current command going to Coil 1/Pump Manifold
Valve.

PUMP MANFLD
FDBK

2

XXXXmA

Current returning from Coil 1/Pump Manifold
Valve.

RT LIFT ISOL CMD:

2

XXXXmA

Current command going to Coil 2/Right Lift
Isolation Valve.

RT LFT ISOL FDB:

2

XXXXmA

Current returning from Coil 2/Right Lift Isolation
Valve.

LT LIFT ISOL CMD:

2

XXXXmA

Current command going to Coil 3/Left Lift Isolation
Valve.

LT LFT ISOL FDB:

2

XXXXmA

Current returning from Coil 3/Left Lift Isolation
Valve.

BOOM RIDE CMD:

2#

XXXXmA

Current command going to Coil 4/Boom Ride
Mode Valve.

BOOM RIDE FDB:

2#

XXXXmA

Current returning from Coil 4/Boom Ride Mode
Valve.

ISP LIFT VEL:

2

±XX.XX kph

Velocity command from ISP for Lift Valve.

ISP TELE VEL:

2

±XX.XX kph

Velocity command from ISP for Telescope Valve.

ISP FORK VEL:

2

±XX.XX kph

Velocity command from ISP for Fork Valve.

ISP AUX VEL:

2

±XX.XX kph

Velocity command from ISP for Auxiliary
Hydraulics part of Fork Valve.

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter

(Displayed on

Analyzer 1

st

Line)

Parameter Value

(Displayed on

Analyzer 2

nd

Line)

Description

Advertising