9.49

G10-55A & G12-55A AccuPlace

Electrical System

9.15.7

Diagnostics

The table below lists Diagnostic Help Messages that the
Control System shall communicate to the Analyzer. The
goal is to help locate the source of any problem which
occurs on the vehicle.

Note: All items are available in Access Level 3, unless
designated with a superscript of the lowest access level
in which the items can be displayed (i.e., "PUMP
MANFLD CMD2" denotes that this parameter is available
in Access Levels 1, and 2).

#

Indicates that parameter should be displayed only if the

machine is configured to utilize the component.

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter

(Displayed on

Analyzer 1

st

Line)

Parameter Value

(Displayed on

Analyzer 2

nd

Line)

Description

GROUND:

AP FLT RST SW:

CLOSED/OPEN

Displays status of AccuPlace Fault Reset switch.

CONT AUX HYD SW: CLOSED/OPEN

Displays status of Continuous Auxiliary
Hydraulics switch.

BOOM RIDE SW:

#

CLOSED/OPEN

Displays status of Boom Ride Mode Enable
switch.

AP MODE LAMP:

ON/OFF

Displays status of AccuPlace Mode Lamp.

AP FLT RST LAMP:

ON/OFF

Displays status of User Fault Lamp.

BOOM RIDE LAMP:

#

ON/OFF

Displays status of Boom Ride Mode Lamp.

LIFT CMD:

UP/DOWN XXX.X% Displays reprocessed joystick lift direction &

demand.

TELE CMD:

IN/OUT XXX.X%

Displays reprocessed joystick telescope switch
direction & demand.

FORK CMD:

UP/DOWN XXX.X% Displays reprocessed joystick fork lift direction &

demand.

AUX CMD:

AUX 1/AUX 2
XXX.X%

Displays reprocessed joystick Auxiliary
Hydraulics direction & demand.

SWAY OUTPUT

LEFT/RIGHT
XXX.X%

Displays UGM sway output command direction &
demand.

SWAY CMD:

LEFT/RIGHT
XXXXmA

Displays UGM sway output current command
direction & demand.

SWAY FDBK:

XXXXmA

Current feedback measured on Sway Valve
Return.

LT STAB OUTPUT:

UP/DOWN XXX.X% Displays UGM Left Stabilizer output command

direction & demand.

LT STAB CMD:

UP/DOWN XXXXmA Displays UGM Left Stabilizer output current

command direction & demand.

LT STAB FDBK:

XXXXmA

Current feedback measured on Left Stabilizer
Valve Return.

RT STAB OUTPUT:

UP/DOWN XXX.X% Displays UGM Right Stabilizer output command

direction & demand.

RT STAB CMD:

UP/DOWN XXXXmA Displays UGM Right Stabilizer output command

direction & demand.