9.42

G10-55A & G12-55A AccuPlace

Max Right Stabilizer Up Duty Cycle

“RT STABILIZER UP MAX”

1300ma

1000-2000ma

Min Right Stabilizer Down Duty Cycle

“RT STABILIZER DN MIN”

600ma

400-1000ma

Max Right Stabilizer Down Duty Cycle

“RT STABILIZER DN MAX”

1300ma

1000-2000ma

Reduced left stabilizer function speed

“LT STABILIZER CREEP”

800ma

600-1400ma

Reduced right stabilizer function speed

“RT STABILIZER CREEP”

800ma

600-1400ma

SWAY JOYSTICK

Low Center Deadband Voltage (5V supply)

“DEADBAND LOW”

2.3V

1.90-2.50V

High Center Deadband Voltage (5V supply)

“DEADBAND HIGH”

2.7V

2.20-3.00V

Low End Voltage

(min command; 5V supply)

“MIN VOLTAGE”

0.5V

0.30-0.70V

High End Voltage

(max command; 5V supply)

“MAX VOLTAGE”

4.4V

4.00-4.60V

Low End Fault Voltage (5V supply)

“FAULT LOW”

0.25V

0.10-0.40V

High End Fault Voltage (5V supply)

“FAULT HIGH”

4.75V

4.40-4.90V

AUX JOYSTICK

Low Center Deadband Voltage (5V supply)

“DEADBAND LOW”

2.3V

1.90-2.50V

High Center Deadband Voltage (5V supply)

“DEADBAND HIGH”

2.7V

2.20-3.00V

Low End Voltage (min command; 5V supply)

“MIN VOLTAGE”

0.5V

0.30-0.70V

High End Voltage (max command; 5V

supply)

“MAX VOLTAGE”

4.4V

4.00-4.60V

Low End Fault Voltage (5V supply)

“FAULT LOW”

0.25V

0.10-0.40V