JLG G12-55A AccuPlace Service Manual User Manual

Page 201

Advertising
background image

9.83

G10-55A & G12-55A AccuPlace

Electrical System

TELESCOPE
VALVE COIL 2 –
SHORT TO
BATTERY

4557

Tele valve controller detects
uncommanded current in
feedback circuit.

Y

Check for continuity through this circuit.

Inspect wiring for physical damage.

Disconnect TELE V2 coil connection,
cycle power, and verify that fault changes
to DTC 4556 (open circuit); then check the
V2 coil connector/pins and wiring. If the
fault remains, remove the 12-pin
connector and verify the integrity of the
connector pins of both the controller and
harness, then dislodge TELE V2 RTN pin
from the connector, reconnect the 12-pin
connector, and cycle power. If the fault still
remains, dislodge the TELE V2 pin,
reconnect, and cycle power. If the fault
persists, continue this pattern until all the
wires are dislodged. If the only wires
remaining are power and CAN Bus and a
STB fault still exists, then the fault lies
within the valve controller and
replacement is necessary.

TELESCOPE
VALVE COIL 3 –
SHORT TO
BATTERY

4559

Tele valve controller detects
uncommanded current in
feedback circuit.

Y

Check for continuity through this circuit.

Inspect wiring for physical damage.

Disconnect TELE V3 coil connection,
cycle power, and verify that fault changes
to DTC 4558 (open circuit); then check the
V3 coil connector/pins and wiring. If the
fault remains, remove the 12-pin
connector and verify the integrity of the
connector pins of both the controller and
harness, then dislodge TELE V3 RTN pin
from the connector, reconnect the 12-pin
connector, and cycle power. If the fault still
remains, dislodge the TELE V3 pin,
reconnect, and cycle power. If the fault
persists, continue this pattern until all the
wires are dislodged. If the only wires
remaining are power and CAN Bus and a
STB fault still exists, then the fault lies
within the valve controller and
replacement is necessary.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising