JLG G12-55A AccuPlace Service Manual User Manual

Page 162

Advertising
background image

Electrical System

9.44

G10-55A & G12-55A AccuPlace

Deceleration down

“LIFT DN DECEL”

0.0500 kph

0.006-0.2 kph

Acceleration in

“TELE IN ACCEL”

0.0200 kph

0.01-1.0 kph

Deceleration in

“TELE IN DECEL”

0.0500 kph

0.02-1.0 kph

Acceleration out

“TELE OUT ACCEL”

0.0200 kph

0.01-1.0 kph

Deceleration out

“TELE OUT DECEL”

0.0500 kph

0.02-1.0 kph

Acceleration up

“FORK UP ACCEL”

1.000 kph

0.01-1.0 kph

Deceleration up

“FORK UP DECEL”

0.100 kph

0.02-1.0 kph

Acceleration down

“FORK DN ACCEL”

1.000 kph

0.01-1.0 kph

Deceleration down

“FORK DN DECEL”

0.100 kph

0.02-1.0 kph

Low Standard Speed

“LOW SPEED MLTPR”

0.400 0.2-0.5

Medium Speed

“MED SPEED MLTPR”

0.800 0.5-0.9

End of Stroke Slowdown Speed Multiplier (to

be used for all function soft stops)

“SOFT ZONE MLTPR”

0.400 0.2-0.9

Lift Up End of Stroke Slowdown Threshold

“LIFT UP SOFT ZN”

65.0 DEG

55.0-75.0 DEG

Lift Down End of Stroke Slowdown

Threshold

“LIFT DN SOFT ZN”

-2.0 DEG

-8.0 - (+2.0) DEG

Tele Out End of Stroke Slowdown Threshold

“TELE CYL OUT SFT ZONE”

11.48 FT

(3500mm)

10.16-12.13 FT

(3097-3697mm)

Tele In End of Stroke Slowdown Threshold

“TELE CYL IN SFT ZONE”

0.49FT

(150mm)

0-1.96FT

(0-597mm)

Function

Personality

Default Setting

Adjustment Range

Advertising