9.91

G10-55A & G12-55A AccuPlace

Electrical System

LIFT VALVE –
TEMPERATURE
DISAGREEMENT

4590

Lift valve controller detects
both Temperature Sensors 1
and 2 out of range or their
readings differ by more than
20° C.

N

Cycle power to clear DTC; if DTC still
present, controller replacement required.
Ensure transducer gaskets are in place
and reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”).

CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.

Removing controller may cause cylinder
leakage. Brace/block boom before
removing controller.

TELESCOPE
VALVE –
TEMPERATURE
DISAGREEMENT

4591

Tele valve controller detects
both Temperature Sensors 1
and 2 out of range or their
readings differ by more than
20° C.

N

Cycle power to clear DTC; if DTC still
present, controller replacement required.
Ensure transducer gaskets are in place
and reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”).

CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.

Removing controller may cause cylinder
leakage. Brace/block boom before
removing controller.

FORK VALVE –
TEMPERATURE
DISAGREEMENT

4592

Fork valve controller detects
both Temperature Sensors 1
and 2 out of range or their
readings differ by more than
20° C.

N

Cycle power to clear DTC; if DTC still
present, controller replacement required.
Ensure transducer gaskets are in place
and reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”).

CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.

ISP –
TEMPERATURE
DISAGREEMENT

4593

ISP controller detects both
Temperature Sensors 1 and
2 out of range or their
readings differ by more than
20° C.

N

Cycle power to clear DTC; if DTC still
present, controller replacement required.
Ensure transducer gaskets are in place
and reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”).

CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.

LIFT VALVE –
TEMPERATURE
TOO HIGH

4594

Lift valve controller detects
oil temperature greater than
100° C

N

Oil is near highest recommended
operating temperature; slightly reduced
machine duty cycle is recommended.

TELESCOPE
VALVE –
TEMPERATURE
TOO HIGH

4595

Tele valve controller detects
oil temperature greater than
100° C

N

Oil is near highest recommended
operating temperature; slightly reduced
machine duty cycle is recommended.