JLG G12-55A AccuPlace Service Manual User Manual

Page 191

Advertising
background image

9.73

G10-55A & G12-55A AccuPlace

Electrical System

REAR
STABILIZER ONE
VALVE – OPEN
CIRCUIT

33350 Feedback voltage on UGM

pin J1-13 indicates STB
fault.

N

Check for continuity through this circuit.

Inspect wiring for physical damage.

Note: An open circuit voltage of nearly
8.0V exists on this UGM pin for circuit
diagnostic purposes.

REAR
STABILIZER TWO
VALVE – SHORT
TO BATTERY

33351 Feedback voltage on UGM

pin J1-2 indicates STB fault.

N

Check for continuity through this circuit.

Inspect wiring for physical damage.

With the engine off, but controller power
on, and with the valve disconnected, the
open circuit voltage at the valve connector
should be around 8.0V or less. If not,
continue tracing the circuit back toward
UGM, making measurements to
determine where the STB exists. Once
isolated, perform continuity check to
narrow source of problem.

REAR
STABILIZER TWO
VALVE – SHORT
TO GROUND

33352 Voltage on UGM pin J1-2

while driving coil indicates
STG condition.

N

Check for continuity through this circuit.

Inspect wiring for physical damage. The
low side of this coil should be within 1ohm
resistance to the negative battery
terminal.

REAR
STABILIZER TWO
VALVE – OPEN
CIRCUIT

33353 Feedback voltage on UGM

pin J1-2 indicates STB fault.

N

Check for continuity through this circuit.

Inspect wiring for physical damage.

Note: An open circuit voltage of nearly
8.0V exists on this UGM pin for circuit
diagnostic purposes.

ENGINE
TROUBLE CODE

437

Engine reports fault and
UGM initiates display of
SPN/FMI.

N

This fault provides an Suspect Parameter
Number/Failure Mode Identifier to be used
in conjunction with the engine
manufacturer's instructions.

BATTERY
VOLTAGE TOO
LOW – SYSTEM
SHUTDOWN

441

UGM measures battery
voltage < 9V for more than 3
seconds (excluding during
engine cranking).

Y

Recharge batteries or check for damaged
batteries.

BATTERY
VOLTAGE TOO
HIGH – SYSTEM
SHUTDOWN

442

UGM measures battery
voltage > 16V for more than
3 seconds (excluding during
engine cranking).

Y

May be due to improper battery charging
or incorrect voltage batteries being used.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)