9.87

G10-55A & G12-55A AccuPlace

Electrical System

LIFT RIGHT
ISOLATION
VALVE – SHORT
TO BATTERY

4573

ISP controller detects
uncommanded current in
feedback circuit on the right
Lift Isolation valve coil.

Y

Check for continuity through this circuit.

Inspect wiring for physical damage.

Disconnect RT LIFT ISOL VLV coil
connection, cycle power, and verify that
fault changes to DTC 4572 (open circuit);
then check the RT LIFT ISOL VLV coil
connector/pins and wiring. If the fault
remains, remove the 12-pin connector and
verify the integrity of the connector pins of
both the controller and harness, then
dislodge RT LIFT ISOL VLV RTN pin from
the connector, reconnect the 12-pin
connector, and cycle power. If the fault still
remains, dislodge the RT LIFT ISOL VLV
signal pin, reconnect, and cycle power. If
the fault persists, continue this pattern
until all the wires are dislodged. If the only
wires remaining are power and CAN Bus
and a STB fault still exists, then the fault
lies within the controller and replacement
is necessary.

LIFT LEFT
ISOLATION
VALVE – SHORT
TO BATTERY

4575

ISP controller detects
uncommanded current in
feedback circuit on the left
Lift Isolation valve coil.

Y

Check for continuity through this circuit.

Inspect wiring for physical damage.

Disconnect LT LIFT ISOL VLV coil
connection, cycle power, and verify that
fault changes to DTC 4574 (open circuit);
then check the LT LIFT ISOL VLV coil
connector/pins and wiring. If the fault
remains, remove the 12-pin connector and
verify the integrity of the connector pins of
both the controller and harness, then
dislodge LT LIFT ISOL VLV RTN pin from
the connector, reconnect the 12-pin
connector, and cycle power. If the fault still
remains, dislodge the RT LIFT ISOL VLV
signal pin, reconnect, and cycle power. If
the fault persists, continue this pattern
until all the wires are dislodged. If the only
wires remaining are power and CAN Bus
and a STB fault still exists, then the fault
lies within the controller and replacement
is necessary.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)