9.85

G10-55A & G12-55A AccuPlace

Electrical System

FORK VALVE
COIL 2 – SHORT
TO BATTERY

4565

Fork valve controller detects
uncommanded current in
feedback circuit.

Y

Check for continuity through this circuit.

Inspect wiring for physical damage.

Disconnect FORK V2 coil connection,
cycle power, and verify that fault changes
to DTC 4564 (open circuit); then check the
FORK V2 coil connector/pins and wiring.
If the fault remains, remove the 12-pin
connector and verify the integrity of the
connector pins of both the controller and
harness, then dislodge FORK V2 RTN pin
from the connector, reconnect the 12-pin
connector, and cycle power. If the fault still
remains, dislodge the FORK V2 pin,
reconnect, and cycle power. If the fault
persists, continue this pattern until all the
wires are dislodged. If the only wires
remaining are power and CAN Bus and a
STB fault still exists, then the fault lies
within the valve controller and
replacement is necessary.

AUX VALVE COIL
1 – SHORT TO
BATTERY

4567

Fork valve controller detects
uncommanded current in
feedback circuit.

Y

Check for continuity through this circuit.

Inspect wiring for physical damage.

Disconnect AUX V1 coil connection, cycle
power, and verify that fault changes to
DTC 4566 (open circuit); then check the
AUX V1 coil connector/pins and wiring. If
the fault remains, remove the 12-pin
connector and verify the integrity of the
connector pins of both the controller and
harness, then dislodge AUX V1 RTN pin
from the connector, reconnect the 12-pin
connector, and cycle power. If the fault still
remains, dislodge the AUX V1 pin,
reconnect, and cycle power. If the fault
persists, continue this pattern until all the
wires are dislodged. If the only wires
remaining are power and CAN Bus and a
STB fault still exists, then the fault lies
within the valve controller and
replacement is necessary.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)