9.103

G10-55A & G12-55A AccuPlace

Electrical System

BOOM ANGLE
SENSOR – NOT
DETECTING
CHANGE

8463

Controls determine the
boom has a slow response
to commands.

Y

Fault may occur from a stalled boom.

Cycle power to see if fault clears.

Check that sensors are securely mounted
and not damaged or bent. Verify all
hardware is tight.

Lift boom through range to verify Left and
Right Boom Angle sensors are tracking
smoothly via Analyzer under Diagnostics/
Boom Components.

If not tracking well, calibrate boom angle
sensors.
Refer to Section 9.15.5, “Calibrations.”

BOOM LENGTH
SENSOR – NOT
CALIBRATED

8464

Out-of-range default offset
value not overwritten.

N

Check that boom length sensor is securely
mounted and undamaged.

Calibrate boom length sensor. Refer to
Section 9.15.5, “Calibrations.”

FORK POSITION
SENSOR – NOT
CALIBRATED

8465

Out-of-range default offset
value not overwritten.

N

Calibrate fork sensor. Refer to Section
9.15.5, “Calibrations.”

NEW BOOM
LENGTH
SENSOR
DETECTED

8466

UGM determines that Boom
Length Sensor serial number
differs from the sensor used
for last calibration.

N

Calibrate boom length sensor. Refer to
Section 9.15.5, “Calibrations.”

NEW FORK
POSITION
SENSOR
DETECTED

8467

UGM determines that Fork
Sensor serial number differs
from the sensor used for last
calibration.

N

Calibrate fork sensor. Refer to Section
9.15.5, “Calibrations.”

BOOM LENGTH
SENSOR - NOT
DETECTING
CHANGE

8468

Controls determine slow
response to commands. Not
reported if cab joystick not
commanding motion.

Y

Fault may occur from a stalled boom.

Cycle power to see if fault clears.

Check that boom length sensor is securely
mounted and undamaged. Verify all
hardware is tight.

Extend boom through range to verify Tele
Length sensor is tracking smoothly via
Analyzer under Diagnostics/Boom
Components.

If not tracking well calibrate boom length
sensor.
Refer to Section 9.15.5, “Calibrations.”

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)