JLG G12-55A AccuPlace Service Manual User Manual

Page 185

Advertising
background image

9.67

G10-55A & G12-55A AccuPlace

Electrical System

LEFT
STABILIZER
JOYSTICK – OUT
OF RANGE HIGH

2363

The Left Stabilizer joystick
voltage has reached the high
error limit defined in
Personalities.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Left
Stabilizer joystick and an adjacent Mini
Joystick to determine whether the Left
Stabilizer joystick is faulty. If the joystick is
fine, focus troubleshooting efforts on the
connector and wiring as detailed in DTC
2128.

Check continuity of wiring connections.

LEFT
STABILIZER
JOYSTICK – OUT
OF RANGE LOW

2364

The Left Stabilizer joystick
voltage has reached the low
error limit defined in
Personalities.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Left
Stabilizer joystick and an adjacent Mini
Joystick to determine whether the Left
Stabilizer joystick is faulty. If the joystick is
fine, focus troubleshooting efforts on the
connector and wiring as detailed in DTC
2128.

Check continuity of wiring connections.

RIGHT
STABILIZER
JOYSTICK –
NEUTRAL
DISAGREEMENT

2365

The Right Stabilizer joystick
is within its deadband and
one of the directional
switches is closed or the
joystick is outside its
deadband and the
respective directional switch
is not closed; debounce 2
seconds.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Right
Stabilizer joystick and an adjacent Mini
Joystick to determine whether the Left
Stabilizer joystick is faulty. If the joystick is
fine, focus troubleshooting efforts on the
connector and wiring as detailed in DTC
2129.

Check continuity of wiring connections.

RIGHT
STABILIZER
JOYSTICK – OUT
OF RANGE HIGH

2366

The Right Stabilizer joystick
voltage has reached the high
error limit defined in
Personalities.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Right
Stabilizer joystick and an adjacent Mini
Joystick to determine whether the Left
Stabilizer joystick is faulty. If the joystick is
fine, focus troubleshooting efforts on the
connector and wiring as detailed in DTC
2129.

Check continuity of wiring connections.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising
This manual is related to the following products: