9.93

G10-55A & G12-55A AccuPlace

Electrical System

LIFT VALVE –
WIRING NOT
MAPPED
PROPERLY

45103 The order of the Lift Valve

current feedback wiring in
the 12-pin connector does
not match what the controller
expects.

Y

Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Check the integrity of the
controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.

Verify that the proper controller is
installed. Disconnect the ISP, Tele Valve,
and Fork Valve controllers and cycle
power. Under Diagnostics/Versions, verify
that only the UGM, Joystick and Lift Valve
are reporting a software version (??? for
the other controllers).

TELESCOPE
VALVE – WIRING
NOT MAPPED
PROPERLY

45104 The order of the Tele Valve

current feedback wiring in
the 12-pin connector does
not match what the controller
expects.

Y

Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Check the integrity of the
controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.

Verify that the proper controller is
installed. Disconnect the ISP, Lift Valve,
and Fork Valve controllers and cycle
power. Under Diagnostics/Versions, verify
that only the UGM, Joystick and Tele
Valve is reporting a software version (???
for the other controllers).

FORK VALVE –
WIRING NOT
MAPPED
PROPERLY

45105 The order of the Fork Valve

current feedback wiring in
the 12-pin connector does
not match what the controller
expects.

Y

Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Check the integrity of the
controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.

Verify that the proper controller is
installed. Disconnect the ISP, Lift Valve,
and Tele Valve controllers and cycle
power. Under Diagnostics/Versions, verify
that only the UGM, Joystick and Fork
Valve is reporting a software version (???
for the other controllers).

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)