JLG G12-55A AccuPlace Service Manual User Manual

Page 218

Advertising
background image

Electrical System

9.100

G10-55A & G12-55A AccuPlace

CHASSIS TILT
SENSOR NOT
CALIBRATED

813

Out-of-range default offset
value not overwritten.

Y

Calibrate tilt sensor.
Refer to Section 9.15.5, “Calibrations.”

CHASSIS TILT
SENSOR OUT OF
RANGE

814

Sensor reads outside range
of -25° < X < 25° for 2
seconds.

Y

Fault will occur if machine is physically
angled beyond its permitted ranges.
Otherwise, the tilt sensor located within
the UGM may be suspect.

Cycle power to see if fault clears.

Calibrate tilt sensor, if necessary. Refer to
Section 9.15.5, “Calibrations.”

CHASSIS TILT
SENSOR
DISAGREEMENT

815

(Sensor 1 reading – Sensor
2 reading) >= 3.0° for 5
seconds.

Y

Fault may occur if operating under
extremely rough conditions.

Cycle power to see if fault clears.

Otherwise, calibrate tilt sensor.

BOOM ANGLE
SENSOR
DISAGREEMENT

841

Boom Angle Left and Right
sensors disagree by more
than the allowed amount set
in Personalities for more
than 2 seconds or greater
than 10 degrees for 40ms.

Y

Check that sensors are securely mounted
and not damaged or bent. Verify all
hardware is tight. Lift boom through range
to verify tracking of sensors via Analyzer
under Diagnostics/Boom Components..

If tracking appears to be slightly off,
calibrate Boom Angle sensor. Refer to
Section 9.15.5, “Calibrations.”

BOOM ANGLE
SENSOR LEFT –
OUT OF RANGE
LOW

8455

Calibrated Left Boom Angle
less than -15° for more than
2 seconds.

Y

Check that sensors are securely mounted
and not damaged or bent. Verify all
hardware is tight. Lift boom through range
to verify Left Boom Angle tracks smoothly
via Analyzer under Diagnostics/Boom
Components.

If tracking appears to be slightly off,
calibrate boom angle sensors. Refer to
Section 9.15.5, “Calibrations.”

BOOM ANGLE
SENSOR LEFT –
OUT OF RANGE
HIGH

8456

Calibrated Left Boom Angle
greater than +85° for more
than 2 seconds.

Y

Check that sensors are securely mounted
and not damaged or bent. Verify all
hardware is tight. Lift boom through range
to verify Left Boom Angle tracks smoothly
via Analyzer under Diagnostics/Boom
Components.

If tracking appears to be slightly off,
calibrate boom angle sensors. Refer to
Section 9.15.5, “Calibrations.”

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising