9.41

G10-55A & G12-55A AccuPlace

Electrical System

9.15.3

Personality Settings

The following parameters are given to define how each
function shall perform when accessed. All parameters
can be viewed from Access Level 3, but can only be
modified in Access Level 2. Access Level 2 Code: 33271.

Function

Personality

Default Setting

Adjustment Range

FRAME SWAY

Acceleration

“ACCEL”

0.1 second

0.1-1.0 second

Deceleration

“DECEL”

0.1 second

0.1-0.5 second

Min Left Sway Duty Cycle

“MIN LEFT”

550ma

400-1000ma

Max Left Sway Duty Cycle

“MAX LEFT”

1700ma

1000-2000ma

Min Right Sway Duty Cycle

“MIN RIGHT”

550ma

400-1000ma

Max Right Sway Duty Cycle

“MAX RIGHT”

1700ma

1000-2000ma

Reduced sway function speed

“CREEP RT”

1000ma

600-1400ma

Reduced sway function speed

“CREEP LT”

1000ma

600-1400ma

STABILIZER

Left acceleration up

0.1 second

0.1-1.0 second

Left deceleration up

0.1 second

0.1-0.5 second

Right acceleration dn

0.1 second

0.1-1.0 second

Right deceleration dn

0.1 second

0.1-0.5 second

Min Left Stabilizer Up Duty Cycle

“LT STABILIZER UP MIN”

600ma

400-1000ma

Max Left Stabilizer Up Duty Cycle

“LT STABILIZER UP MAX”

1300ma

1000-2000ma

Min Left Stabilizer Down Duty Cycle

“LT STABILIZER DN MIN”

600ma

400-1000ma

Max Left Stabilizer Down Duty Cycle

“LT STABILIZER DN MAX”

1300ma

1000-2000ma

Min Right Stabilizer Up Duty Cycle

“RT STABILIZER UP MIN”

600ma

400-1000ma