Problem 2. “low or no pump flow or pressure – JLG G12-55A AccuPlace Service Manual User Manual

Page 74

Advertising
background image

Transmission

6.8

G10-55A & G12-55A AccuPlace

2. Low or no pump flow or

pressure.

1. Low oil level.

1. Fill transmission to correct level

with Mobilfluid 424

®

(ISO Grade 46). Refer to
Section 2.4, “Fluid and
Lubricant Capacities.”

2. Transmission filled with incorrect

oil, or oil contaminated.

2. Drain transmission and fill to

correct level with Mobilfluid 424

®

(ISO Grade 46). Refer to
Section 2.4, “Fluid and
Lubricant Capacities.”

3. Pump suction pipe screen

clogged.

3. Clean, repair and/or replace

suction pipe.

4. Central shaft damaged.

4. Replace central shaft.

5. Pump worn or damaged.

5. Repair or replace pump

assembly.

6. Electronic control function not

operating properly.

6. Check for DTC. Refer to Section

9.15.8, “Diagnostic Trouble
Code (DTC) Table.”
Refer to Section 9.15.2, “Debug
Functionality.”

3. Low clutch pressure.

1. Incorrect oil level.

1. Fill transmission to correct level

with Mobilfluid 424

®

(ISO Grade 46). Refer to
Section 2.4, “Fluid and
Lubricant Capacities.”

2. Main pressure valve stuck open.

2. Clean the valve spool and

housing.

3. Broken or worn coupling shaft or

piston o-rings.

3. Replace coupling and/or o-rings.

4. Pressure reducing valve stuck

open.

4. Clean the valve spool and

housing.

Problem

Cause

Remedy