JLG G12-55A AccuPlace Service Manual User Manual

Page 173

Advertising
background image

9.55

G10-55A & G12-55A AccuPlace

Electrical System

FORK VALVE

2

FORK PRESS-HEAD: XXXX.X PSI

Pressure reported from Work Port 1 (Head).

FORK PRESS-LS:

XXXX.X PSI

Pressure reported from Fork Shuttle Valve.

FORK TEMP-HEAD:

±XXXDEG C

Temperature reported from Work Port 1.

FORK TEMP-LS:

±XXXDEG C

Temperature reported from Fork Shuttle Valve.

FORK COIL 1 CMD:

XXXXmA

Current commanded to Fork Coil 1.

FORK COIL 1 FDBK:

XXXXmA

Current returning from Fork Coil 1.

FORK COIL 2 CMD:

XXXXmA

Current commanded to Fork Coil 2.

FORK COIL 2 FDBK:

XXXXmA

Current returning from Fork Coil 2.

AUX COIL 1 CMD:

XXXXmA

Current commanded to Fork Coil 3.

AUX COIL 1 FDBK:

XXXXmA

Current returning from Fork Coil 3.

AUX COIL 2 CMD:

XXXXmA

Current commanded to Fork Coil 4.

AUX COIL 2 FDBK:

XXXXmA

Current returning from Fork Coil 4.

CALIBRATION
DATA

2

BOOM ANGLE LT:

CAL LOW XXXXX

Calibration offset for Boom Down of Boom Angle
Left Sensor (CAN).

BOOM ANGLE LT:

CAL HIGH XXXXX

Calibration offset for Boom Up of Boom Angle Left
Sensor (CAN).

BOOM ANGLE RT:

CAL LOW XXXXX

Calibration offset for Boom Down of Boom Angle
Right Sensor (Analog).

BOOM ANGLE RT:

CAL HIGH XXXXX

Calibration offset for Boom Up of Boom Angle
Right Sensor (Analog).

TELE SENSOR CAL: RET XXXXX

Calibration offset for Boom Retracted of Tele
Length Sensor.

TELE SENSOR CAL: EXT XXXXX

Calibration offset for Boom Extended of Tele
Length Sensor.

FORK SENSOR CAL: LOW XXXXX

Calibration offset for Fork Down of Fork Angle
Sensor.

FORK SENSOR CAL: HIGH XXXXX

Calibration offset for Fork Up of Fork Angle
Sensor.

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter

(Displayed on

Analyzer 1

st

Line)

Parameter Value

(Displayed on

Analyzer 2

nd

Line)

Description