JLG G12-55A AccuPlace Service Manual User Manual

Page 210

Advertising
background image

Electrical System

9.92

G10-55A & G12-55A AccuPlace

FORK VALVE –
TEMPERATURE
TOO HIGH

4596

Lift valve controller detects
oil temperature greater than
100° C.

N

Oil is near highest recommended
operating temperature; slightly reduced
machine duty cycle is recommended.

ISP –
TEMPERATURE
TOO HIGH

4597

ISP controller detects oil
temperature greater than
100° C.

N

Oil is above highest recommended
operating temperature; reduced machine
duty cycle is required. Machine boom
motion is reduced to Medium speed until
temperature decreases.

LIFT VALVE –
TEMPERATURE
TOO HIGH –
MACHINE AT
CUTBACK

4598

Lift valve controller detects
oil temperature greater than
105° C.

N

Oil is above highest recommended
operating temperature; reduced machine
duty cycle is required. Machine boom
motion is reduced to Medium speed until
temperature decreases.

TELESCOPE
VALVE –
TEMPERATURE
TOO HIGH –
MACHINE AT
CUTBACK

4599

Tele valve controller detects
oil temperature greater than
105° C.

N

Oil is above highest recommended
operating temperature; reduced machine
duty cycle is required. Machine boom
motion is reduced to Medium speed until
temperature decreases.

FORK VALVE –
TEMPERATURE
TOO HIGH –
MACHINE AT
CUTBACK

45100 Fork valve controller detects

oil temperature greater than
105° C.

N

Oil is above highest recommended
operating temperature; reduced machine
duty cycle is required. Machine boom
motion is reduced to Medium speed until
temperature decreases.

ISP – WIRING
NOT MAPPED
PROPERLY

45102 The order of the ISP current

feedback wiring in the 12-pin
connector does not match
what the controller expects.

Y

Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Next, check the integrity of
the controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.

Verify that the proper controller is
installed. Disconnect the Lift, Tele, and
Fork Valve controllers and cycle power.
Under Diagnostics/Versions, verify that
only the UGM, Joystick and ISP are
reporting a software version (??? for the
other controllers).

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising
This manual is related to the following products: