Electrical System

9.12

G10-55A & G12-55A AccuPlace

c. UGM Communications/Power/Ground

UGM

Connector/Pin

Description

Signal Level

Description/Purpose

J1-4

Rear Stab Valve Gnd

Common ground for the two rear stabilizer

coils; no current feedback

J1-28

Analyzer PWR

Analyzer Power

J1-29

Analyzer RS232 Receive

Analyzer Communication

J1-30

Analyzer RS232 Transmit

Analyzer Communication

J1-31

Analyzer Return

Analyzer Ground

J3-3

Boom Angle Right Sensor

Ground

B-

Analyzer Ground

J3-12

Boom Angle Right Sensor

Power

+5V

regulated

J4-24

V

bat

for Panel Switches

B+ (V

bat

)

UGM provides power for panel switch inputs

J4-25

Mini Joystick Switch Power

B+ (V

bat

)

UGM provides power to Mini Joysticks to

confirm out-of-neutral state

J4-32

Lamp Gnd

GND

Common lamp return

J7-3

Controller Power Enable

B+ (

Power Enable for UGM Logic Circuitry

J7-6

CAN1 Terminator 1

Jumper to J7-17 for 120 ohm termination

J7-13

CAN1 HI

J7-17

CAN1 Terminator 2

Jumper to J7-6 for 120 ohm termination

J7-18

CAN1 Shield

J7-19

Cab Joystick Ground

B-

J7-24

CAN1 LO

J7-25

Mini Joystick Ground

B-

J7-27

Mini Joystick Power

+5V

regulated

J7-34

Cab Joystick Power

B+ (V

bat

)

J8-1

B-

B-

Ground for UGM

J8-2

Switched B+

B+ (V

bat

)

Power to UGM; fused to 25A via F8

J8-4

INCOVA Power

B+ (V

bat

)

Power Enable for UGM Logic Circuitry

J12-3

CAN2 HI

Cab Joystick on CAN2

J12-4

CAN2 LO

J12-5

CAN2 Shield

J12-6

CAN2 Terminator 1

J12-7

CAN2 Terminator 2

Advertising