JLG G12-55A AccuPlace Service Manual User Manual

Page 183

Advertising
background image

9.65

G10-55A & G12-55A AccuPlace

Electrical System

BOOM RIDE
MODE SWITCH
CLOSED AT
POWER UP

2

2355

Boom Ride Mode Switch
read by UGM as closed
during system startup.

N

Turn Boom Ride Mode switch off (open
state), then back on (closed state).

Press button to confirm that button is
functional. If fault persists, check under
Diagnostics/Ground to verify that the
switch changes state. Check to determine
whether a power cycle will clear the DTC.

Check continuity of wiring connections.

AUXILIARY
HYDRAULICS
JOYSTICK –
NEUTRAL
DISAGREEMENT

2356

The Aux Hydraulic joystick is
within its centered deadband
and one of the out-of-neutral
directional switches is closed
or the joystick is outside its
deadband and the
respective directional switch
is not closed.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Aux
Hydraulics joystick and an adjacent Mini
Joystick to determine whether the Aux
Hydraulics joystick is faulty. If the joystick
is fine, focus troubleshooting efforts on the
connector and wiring as detailed in DTC
2127.

Check continuity of wiring connections.

AUXILIARY
HYDRAULICS
JOYSTICK – OUT
OF RANGE HIGH

2357

The Aux Hydraulic joystick
voltage has reached the high
error limit defined in
Personalities.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Auxiliary
Hydraulics joystick and an adjacent Mini
Joystick to determine whether the
Auxiliary Hydraulics joystick is faulty. If the
joystick is fine, focus troubleshooting
efforts on the connector and wiring as
detailed in DTC 2127.

Check continuity of wiring connections.

AUXILIARY
HYDRAULICS
JOYSTICK – OUT
OF RANGE LOW

2358

The Aux Hydraulic joystick
voltage has reached the low
error limit defined in
Personalities.

N

Center joystick and check to see if a power
cycle will clear DTC.

If not, swap connector between Auxiliary
Hydraulics joystick and an adjacent Mini
Joystick to determine whether the
Auxiliary Hydraulics joystick is faulty. If the
joystick is fine, focus troubleshooting
efforts on the connector and wiring as
detailed in DTC 2127.

Check continuity of wiring connections.

Help Message

1

DTC

Fault Condition

(for configurable items,

fault applies only if

configured)

Fault

Requires

AccuPlace

Reset?

Action(s)

Advertising