Ms – motion status – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 119

Advertising
background image

MS – Motion Status

Purpose:
Reports the status of the motion profiling process. MS can be used for detecting the end
of motions: a PTP motion that has reached its target, or a completed PT or PVT motion.

For position control modes (UM=3, 4, 5), MS reports as follows:

Value Description

0

Motor position stabilized. The feedback position is steady within the
ranges defined by TR. Note that value 0 is applicable only when there
is a defined position target, as in PTP.

1 The

reference for the position controller is stationary, or the motor is off

(MO=0).

2 The

reference to the position controller is dynamically controlled by

one of the optional motion profilers: PTP, Jog, PT or PVT.

3 Reserved.

MS reflects only the software motions. It does not indicate anything about the
behavior of the external reference command.

For speed control modes (UM=2), MS reports as follows:

Value Description

0

Not applicable for this mode.

1

The reference to the speed controller equals the speed target.

(This is always the case if no profiler mode is used: PM=0.)

The motor is off (MO=0).

2 The

software

reference to the speed controller differs from the speed

target. In software profiled reference mode (PM=1, RM=0), this is the
case while accelerating, decelerating or smoothing to the JV target speed.

3 Reserved.

Attributes:

Type:

Status report, Integer

Scope:

Program, RS-232, CANopen

Restrictions: None
Unit modes: All
SimplIQ: Similar

See also:

PM

,

RM

,

DV[N]

,

AC

,

DC

,

TR

Application note:

Idle Mode and Motion Status

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

111