Chapter 3: Alphabetical Listing

This chapter lists all the commands in alphabetical order, along with detailed
definitions and examples of each command.

The description of each command includes the following items:

Purpose:

The operation or task of the command

Attributes:

The characteristics of the command

Type:

One of the following:

A command: An instruction to do something. For example, the BG

(Begin Motion) command starts a new motion profile.

A parameter: A data item that may be used later. For example, the AC
(Acceleration) parameter is required for calculating subsequent motions.

A status report: Get a value, such as the motor speed, a digital input

or the reason for the last motor failure.

The parameters and certain commands have numerical values, as follows:

Integer: A 32-bit long integer
Real: A 32-bit floating point number (IEEE style)
String: A set of printable ASCII characters

Integer variables may have the following attributes:

Bit field: The integer should be understood not as a number but rather as a

combination of binary fields. For example, the IP (Digital Input) command reads
many On/Off switches to the same integer, allocating one bit for each.

Option: A selector that may accept one of several options. For example, the

motor direction may be set to forward or reverse, symbolized by the numbers 0
and 1 respectively.

Source:

Defines the “agents” that may use the command, as follows:

RS-232 communication
CANopen communication
User program

The command access rights are not equal for all sources. For example,
CANopen binary interpreter cannot use the string commands listed in
this manual. Another example is the XQ (Execute Program) command
that, of course, cannot be performed from within a program.

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

11

Advertising