Limit ranges – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 21

Advertising
background image

Limit Ranges

The following table lists the value ranges for defining the limits of the system.

Subject Values

Position counter ranges

Main position counter is subjected to a modulo
counting with the following ranges:
XM[1]: Lowest value
XM[2]: Highest value
Range: [-5x10

8

…5x10

8

] counts

Auxiliary position counter is limited to:
YM[1]: Lowest value
YM[2]: Highest value
Range: [-5x10

8

…5x10

8

] counts

Velocity range

Range for Quadrature Encoder:
[-40,000,000…40,000,000] counts/sec

Range for other feedbacks:
[-80,000,000…80,000,000] counts/sec

EF[1]: Filter for main velocity sensor
EF[2]: Filter for auxiliary velocity sensor

Acceleration/Deceleration ranges

Range: [100…1,000,000,000]

Stop deceleration range

Range: [100…1,000,000,000]

Torque limits

Range of torque command is subjected to the
following limits:
CL[1], PL[1]
Range: [-MC…MC]

Note:

The multiplication of the PWM frequency

reduces the torque limit.

Table 3-1: Limit Ranges

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

13