RL - Record Length

Purpose:
Specifies the length of the recorded data, as follows:

Number of Simultaneously
Recorded Signals

Maximum
Record Length

1 4096

2 2048

3 1365

4 1024

Table 3-36: Record Length of Simultaneously Recorded Signals

RL can specify that the signal records will be shorter than the maximum. If RL is set to
a value higher than the maximum record length (for example, RC defines three
recorded signals, but RL=2048), the recorder will still work. The length of the records,
however, will be shorter than RL. The actual size of the recorded data is returned by
WI[21].

Attributes:

Type: Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions:

Recorder inactive (RR=0 or RR=-1)

Default value:

256 (RS), Volatile

Range: [1…4096]
Unit modes: All
Activation:

Next initiation of the recorder (RR).

SimplIQ:

Similar (see note)

Under most circumstances, this command is used only by the Composer

program and the tuning environment.

Notes:

SimplIQ difference: with AR[1]=1, this command refers the motion processor.
On AR[1]=1 (Motion processor recording), the maximum record length differs

from the specification in the table above.

If the drive has stored a previously recorded data vector, setting RL will

invalidate this data. Invalidated data cannot be retrieved.

See also:

RC

,

RG

,

RP[N]

,

RR

,

BH