Dd - can controller status – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 47

Advertising
background image

DD - CAN Controller Status

Purpose:
Returns the status of the CAN controller as a string in hexadecimal form without a
“0x” prefix. DD is valid only for drives that support CAN controllers.

Call DD if you:

Suspect that the CAN controller is in Bus Off (no communication) mode.
Suspect that there are many error frames on the CAN bus.
Wish to monitor the CAN controller error activities.

The DD command reflects object 0x2082 (refer to the Elmo CANopen

Implementation Guide for more information).

DD value reports:

CAN receiver flag, indicating the following states:

Overrun
Bus off
Transmitter error
Receiver error
Transmitter warning
Receiver warning

CAN receive error counter, reflecting the status of the MSCAN receive error

counter.

CAN transmit error counter, reflecting the status of the MSCAN receive error

counter.

Network status, which may be one of the following values:

1: Disconnected
2: Connected
3: Preparing
4: Stopped
5: Operational
127: Pre-operational

All data is received from the hardware.

Attributes:

Type:

Status report, String

Overloaded: No
Source: RS-232,

CANopen

Restrictions: None
Unit modes: All
SimplIQ: Similar

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

39