Bh - get a single recorded signal as hexadecimal – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 30

Advertising
background image

BH - Get a Single Recorded Signal as
Hexadecimal

Purpose:
Uploads the values recorded by the recorder to a host. In response to the BH
command, the sends a recorder data message is Hexa-binary form (A binary stream
represented by printable characters). Although recorded data transmissions may take
long time, the drive can accept new commands and run user program code while
transmitting the recorded data.

Attributes:

Type:

Command, Integer, Bit-field

Source: RS-232
Restrictions:

RR=0 (valid recorder data is ready),

Not while executing a previously-requested

BH=n

command

Unit modes: All
Activation: Immediate
SimplIQ: Similar

Under most circumstances, this command is used only by the tuning

environment.

The BH command is designed to optimize data transfer from the drive to the

host, assuming that the host has the computing power to analyze the drive
message.

See also:

AR[N]

Application note:

The Recorder