Ar[n] – active route array – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 27

Advertising
background image

AR[N] – Active Route array

Purpose:

This command determines that some commands will be routed to the motion
processor instead of the standard processing.

AR[1] =1 sets the recorder to record directly from the motion processor.
AN[2]=1 sets the profiler to work directly from the motion processor.

Attributes:

Type: Parameter,

Real

Source:

Program, RS-232, CANopen

Restrictions: None
Default values:

0 (RS), volatile

Range:

0 or 1

Unit modes: All
Activation: Immediate
SimplIQ: Absent

Typical applications:
Tuning of the motion control parameters at a higher time resolution than is available
for the SimplIQ processor.

Under most circumstances, this command is used only by the tuning

environment.

Note:

If you terminate a tuning environment session abnormally,

the drive may remain with a non-default AR[N] setting. This
may cause abnormal drive behavior. When a tuning
environment session aborts abnormally, it is recommended to
reset the drive by power down.

Application notes:

The recorder

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

19

Advertising