Ve - velocity error – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 181

Advertising
background image

VE - Velocity Error

Purpose:
Reports the velocity tracking error:
VE = DV[2] – VX

If the absolute value of VE exceeds ER[2], motion is aborted and a motion fault code
MF=128 (0x80) is set.

If MO=0, or if the speed controller is not used (UM=1, 3), VE returns 0.

Attributes:

Type:

Status report, Integer

Source:

Program, RS-232, CANopen

Restrictions: None
Unit modes:

UM=2, 4, 5

SimplIQ: Similar

Application note:

The Speed Controller

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

173

Advertising