VE - Velocity Error
Purpose:
Reports the velocity tracking error:
VE = DV[2] – VX
If the absolute value of VE exceeds ER[2], motion is aborted and a motion fault code
MF=128 (0x80) is set.
If MO=0, or if the speed controller is not used (UM=1, 3), VE returns 0.
Attributes:
Type:
Status report, Integer
Source:
Program, RS-232, CANopen
Restrictions: None
Unit modes:
UM=2, 4, 5