Limits the magnitude of the controller command to the maximum allowed range.

This is necessary because even if the software command is generated within the
permitted limits and the external command is also within the permitted limits,
their total value may exceed the permitted limits.

The stop manager prevents the position reference generator from driving the motor to
undesired positions. It does not affect the reference generator.

The commands relevant to the stop manager are:

Command Description

SD

Maximum rate that the motor can accelerate/decelerate

IL[N]

Input logic: define the functions associated with the digital inputs

VH[N],
VL[N]

Maximum allowed controller command

XM[N],
YM[N]

Modulo count for main and auxiliary sensors

Table 6-17: Stop Manager Commands

6.3.2

Stop Manager Internal Elements

The stop manager is depicted in the following diagram:

Position

com m and

(Software and

External)

Clip Position com m and

to range

Select zero

if hard-stop

P revent backwards m otion

Select

direction lim it

if RLS

Select

direction lim it

if RLS

Prevent Forward Motion

Rate &

Acceleration

lim iter

Position com m and to

m otion controller

1

2

3

4

5

Figure 6-14: Stop Manager Block Diagram

SimplIQ for Steppers Application Note

The Position Reference Generator

MAN-STECR (Ver. 1.1)

79