HP - Halt Program Execution

Purpose:
Stops the execution of the user program and the automatic routines. The HP command
freezes the status of the program and does not reset it. A later XC command will
resume the program. Pending interrupts will remain pending.

An HP command issued when no program is running does nothing and sets no error
code.

Attributes:

Type:

Command, No value

Source: RS-232,

CANopen

Restrictions: None
Unit modes: All
Activation: Immediate
SimplIQ for Steppers: Similar

The HP command, together with a later XC command, may be used if a

communicated command sequence must be executed consecutively, without
program interference.

See also:

KL

,

XQ

,

XC