RR - Activate Recorder/Get Recorder Status

Purpose:
Launches the recorder, kills an on-going recording process or retrieves the recorder
status. The RR command has the following options:

RR
Value

Meaning

0

Kill the recorder (do nothing if the recorder is not active).

1

Start recording at the next BG command.

2

Start recording immediately.

3

Arm the recorder with the trigger settings of the RP[N] parameters.

Table 3-40: RR Command Options

As a status report, RR may return the following values:

RR
Report

Meaning

-1

There is no valid data in the recorder.

0

The recorder action is complete and it is loaded with valid data.

1 - 3

Waiting for the completion of RR=1, RR=2 or RR=3, respectively. The
report value 3 does not indicate if the recorder is already recording or
just waiting for a trigger. If this differentiation is required, use the SR
command.

Table 3-41: RR Reports

Attributes:

Type: Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions: None
Default value: -1,

Non-volatile

Range: [0…3]
Unit modes: All
Activation: Immediate
SimplIQ:

Similar (see note)

Under most circumstances, this command is used only by the Composer

program and the tuning environment.

Note:

SimplIQ difference: with AR[1]=1, this command refers to the motion processor.