Uploading recorded data, 7 uploading recorded data, Simpliq – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 311

Advertising
background image

10.1.7 Uploading Recorded Data

The following commands are used to upload recorded data from the drive to a host:

Parameter Description

RR

If zero, indicates that the recorder is ready for data upload

WI[21]

Indicates how much data is actually recorded

RP[8], RP[9]

Defines the part of the signal to be uploaded next

BH

Uploads recorded data command

Table 10-6: Parameters for Uploading Recorded Data

The BH command is used to upload to the host the values recorded by the

SimplIQ

drive recorder. BH optimizes the data transfer, assuming that the host has the
computing power to analyze the

SimplIQ

drive message.

To execute a BH command, valid data must be stored in the recorder. If the data is
valid, the fields of the RC variable define the variables that have been recorded.

The BH=n command uploads the recorded variable defined by RC&n, where & is the
bit-wise AND operator. For example, if RC=7, the command BH=2 will transfer the
variable to be recorded by setting RC=2, because 7&2=2. If the binary representation
of RC&BH includes more than one “1”, the variable with the lowest value will be
uploaded and BH will not return an error.

Example:
If

RC=7

and

BH=3, BH

will upload the recorder variable defined by

RC=2

.

BH=16

will

return an error because

BH&RC=0

.

It is convenient to use hexadecimal notation for the BH command; for example,
BH=0x4000 is more readily understandable than BH=32768.

The BH command can load an entire recorded signal, or a part of one. If RP[8]=0 and
RP[9]=0, BH=n will upload an entire signal. Otherwise, BH will upload the recorded
signal from index RP[8] until index RP[9]. RP[9] must always be less than or equal to
the length of the recorded signal.

The data is uploaded in hexadecimal form in order to minimize transmission time
(relative to ASCII formatted text), while adhering to the ASCII nature of
transmissions. Each data byte is parsed into two nibbles, and the ASCII code of the
nibbles is sent from the controller to the host. For example, the short integer number
43794 has the hexadecimal representation AB12. It will be transmitted as “A” “B” “1”
“2” with the most significant nibble first and the least significant nibble last. The long
integer number 1 will be sent as: “0” “0” “0” “0” “0” “0” “0” “1”.