ElmoMC CANopen DS 301 Implementation Guide User Manual

Page 103

Advertising
background image



Motor Fault Description

Motor Fault
Value (MF
Command)


Error
Code


Error
Register

Resolver or Analog Encoder feedback failed

1

0x7300

0x81

Reserved 1

0x7305

0x21

Reserved 2

0x7306

0x21

Feedback loss: no match between encoder and
Hall locations. Available in encoder + Hall
feedback systems

4 0x7380

0x81

Peak current has been exceeded due to:

ƒ

Drive malfunction

ƒ

Badly-tuned current controller

8 0x8311

0x21

Disabled by Limit switch 0x10

0x5441

0x21

ECAM table problem

0x20

0x5280

0x81

Two digital Hall sensors changed at once; only
one sensor can be changed at a time.

0x40 0x7381

0x81

Speed tracking error DV[2]-VX (for UM=2, 4 or 5)
exceeded speed error limit ER[2], due to:

ƒ

Bad tuning of speed controller

ƒ

Too tight a speed-error tolerance

ƒ

Inability of motor to accelerate to required
speed because line voltage is too low, or
motor is not powerful enough

0x80 0x8480

0x81

Position tracking error DV[3]-PX (UM5) or
DV[3]-PY (UM=4) exceeded position error limit
ER[3], due to:

ƒ

Bad tuning of position or speed controller

ƒ

Too tight a position error tolerance

ƒ

Abnormal motor load, a mechanical limit
reached

0x100 0x8611

0x21

Cannot start due to inconsistent database. This
type of database inconsistency is reflected in
status SR report and in CD CPU dump report.

0x200 0x6320

0x21

Too large a difference in ECAM table entries.

0x400

0x5280

0x81

Heartbeat failure, occurring only if drive is set to
“Abort under heartbeat failure” in a CANopen
network (object 0x6007 in CAN object dictionary
set to 1, malfunction).

0x800 0x8130

0x11

Cannot find electrical zero of motor when
attempting to start motor with an incremental
encoder and no digital Hall sensors. Applied
motor current may not suffice for moving motor
from its place.

0x10000 0x8380

0x81

CANopen DS 301 Implementation Guide

Manufacturer-specific Objects

MAN-CAN301IG (Ver. 2.1)

13-26