Entry description:

Access Read/Write

PDO mapping

No

Value range

No

Default value

128

Object 0x2041: Amplifier-free running timer
This object transmits the accurate 32-bit timer of the drive. The timer has a 1-microsecond
resolution that is updated once in a real-time cycle. The accuracy of the report is
1 microsecond and the resolution is real time.

This object is typically used when the host wants to synchronize records for several slave
nodes. It returns the precise time when the synchronous PDO data has been sampled
(refer to

Chapter 8

).

ƒ

Object description:

Index 2041h

Name

Drive free-running timer

Object code

VAR

Data type

UNSIGNED32

Category

ƒ

Entry description:

Access Read

only

PDO mapping

Yes

Value range

No

Default value

No

Object 0x2082: CAN controller status
This object provides the status of the CAN controller status register.

ƒ

Object description:

Index 2082h

Name CAN

controller

status

Object code

VAR

Data type

UNSIGNED32

Category Optional