Object 0x2041: amplifier-free running timer, Object 0x2082: can controller status, Object 0x2041: amplifier-free running timer -11 – ElmoMC CANopen DS 301 Implementation Guide User Manual
Page 88: Object 0x2082: can controller status -11, 0x2041, 0x2082
Entry description:
Access Read/Write
PDO mapping
No
Value range
No
Default value
128
Object 0x2041: Amplifier-free running timer
This object transmits the accurate 32-bit timer of the drive. The timer has a 1-microsecond
resolution that is updated once in a real-time cycle. The accuracy of the report is
1 microsecond and the resolution is real time.
This object is typically used when the host wants to synchronize records for several slave
nodes. It returns the precise time when the synchronous PDO data has been sampled
(refer to
).
Object description:
Index 2041h
Name
Drive free-running timer
Object code
VAR
Data type
UNSIGNED32
Category
Entry description:
Access Read
only
PDO mapping
Yes
Value range
No
Default value
No
Object 0x2082: CAN controller status
This object provides the status of the CAN controller status register.
Object description:
Index 2082h
Name CAN
controller
status
Object code
VAR
Data type
UNSIGNED32
Category Optional
CANopen DS 301 Implementation Guide
Manufacturer-specific Objects
MAN-CAN301IG (Ver. 2.1)
13-11