Object 0x1016: consumer heartbeat time, Object 0x1016: consumer heartbeat time -12 – ElmoMC CANopen DS 301 Implementation Guide User Manual

Page 63

Advertising
background image

Object 0x1016: Consumer heartbeat time
The consumer heartbeat time defines the expected heartbeat cycle time and thus has to be
higher than the corresponding producer heartbeat time configured on the device
producing this heartbeat. Monitoring starts after the reception of the first heartbeat. If the
consumer heartbeat time is 0, the corresponding entry is not used. The time period must
be a multiple of 1 ms.

UNSIGNED32
MSB


LSB

Bits 31…24

23…16

15…0

Value

0

Node-ID

Heartbeat time, in milliseconds

Encoding

- Unsigned8

Unsigned16

If more than one consumer heartbeat entry is configured for the same Node ID, the
device aborts the SDO download with abort code 0604 0043h.

ƒ

Object description:

Index 1016h

Name

Consumer heartbeat time

Object code

ARRAY

Data type

UNSIGNED32

Category Optional

ƒ

Entry description:

Sub-index 0

Description

Largest supported sub-index

Entry category

Optional

Access Read

only

PDO mapping

No

Value range

1

Default value

1

CANopen DS 301 Implementation Guide