ElmoMC CANopen DS 301 Implementation Guide User Manual

Page 20

Advertising
background image

Name Index

Description

Access

Mapped

Digital input

0x2200

Reflects the digital input (IP)

R

Y

Digital inputs
low byte

0x2201

Reflected Negative limit switch, Positive
limit switch and Home switch.

R Y

User Integer

0x2F00

Provides an array of 24 integer numbers
for general-purpose use.

R Y

User Float Array 0x2F01

Provides an array of 24 floating numbers
for general-purpose use.

R/W Y

ET Array

0x2F02

Enables ECAM table variables (ET[1] to
ET[255]) to be loaded.

R/W Y

PVT buffer head
pointer

0x2F11

PVT motion advance information.

R

Y

PVT buffer tail
pointer

0x2F12

PVT motion advance information.

R

Y

Buffered PTP
remained point

0x2F15

Used to detect number of remaining
points in DSP 402 Profile Position
buffered mode.

R Y

Asynchronous
PDO event

0x2F20

Defines which events emit a PDO.

R/W

N

Emergency event

0x2F21

Defines which events emit an emergency. R/W

N

Bus-off timeout

0x2F22

Defines bus-off timeout, after which CAN
communication will be renewed if SimplIQ
enters bus-off.

R/W N

Digital Input
TPDO Event
Parameters

0x2F23

Defines which digital input transmissions
will activate a TPDO driven by a digital
input event.

R/W N

Last Time Stamp
correction

0x2F30

Difference between last SYNC time and
last Time Stamp.
Serves to estimate how accurately the
internal amplifier's clock is locked on the
master clock.

R Y

Internal µsec
counter at last
SYNC

0x2F31

Internal µsec counter of drive, sampled at
last SYNC. Useful when one drive is used
to synchronize entire network.

R Y

Configuration
object

0x2F40

Configure functionality of the node.

R/W

N

Table 3-1: Object Dictionary

CANopen DS 301 Implementation Guide

The Object Dictionary

MAN-CAN301IG (Ver. 2.1)

3-4