Object 0x1013: high-resolution time stamp, Object 0x1013: high-resolution time stamp -10, 0x1013 – ElmoMC CANopen DS 301 Implementation Guide User Manual
Page 61: 0x1014, Simpliq
Object description:
Index 1012h
Name
COB-ID time stamp message
Object code
VAR
Data type
UNSIGNED32
Category Optional
Entry description:
Access Read/Write
PDO mapping
No
Value range
UNSIGNED32
Default value
100h
According to CiA DSP 301, the 0x1012 object has read/write access, although it
only has read access with
SimplIQ
digital servo drives.
Object 0x1013: High-resolution time stamp
This object contains a time stamp with a 1-microsecond resolution.
Object description:
Index 1013h
Name High
resolution time stamp
Object code
VAR
Data type
UNSIGNED32
Category Optional
Entry description:
Access Read/Write
PDO mapping
No
Value range
0…0xFFFFFFFF
Default value
0
CANopen DS 301 Implementation Guide
Device-specific Objects
MAN-CAN301IG (Ver. 2.1)
12-10