Object 0x2004: ecam data, Object 0x2004: ecam data -3, 0x2004 – ElmoMC CANopen DS 301 Implementation Guide User Manual

Page 80: Fast, Simpliq

Advertising
background image

Notes:
ƒ

The transmission type for mapping this object must be 255; otherwise, an Abort
message (code 0604 0043h) will be transmitted.

ƒ

When this object is used to feed PT reference points to the drive while a PT
motion is executing, the drive automatically enters Online Feed mode, in which
the drive is aware of the position written and takes the following precautions:

ƒ

If the feed is too slow, the drive needs to fetch points not yet programmed,
and the motion will abort with a “Queue underflow” emergency.

ƒ

If the feed is too fast, so that points not yet used are overstruck, the drive will
reject the feed attempt with a “Queue overflow” emergency.

ƒ

The Online Feed mode will continue until at least one setting of PT parameters
has been completed without using the RPDO.

Object 0x2004: ECAM data
This object sets ECAM data for the ECAM table entries.

ƒ

Object description:

Index 2004h

Name ECAM

data

Object code

VAR

Data type

PT DataPar (object 0x41)

Category Optional

ƒ

Entry description:

Access Write

only

PDO mapping

Yes

Value range

No

Default value

No

Notes:
ƒ

The transmission type for mapping this object must be 255; otherwise, an Abort
message (code 0604 0043h) will be transmitted.

ƒ

When this object is used to feed ECAM reference points to the drive, a working
table with a border cannot be used. (Refer to the

SimplIQ

Software Reference

Manual for more information.)

CANopen DS 301 Implementation Guide

Manufacturer-specific Objects

MAN-CAN301IG (Ver. 2.1)

13-3

Advertising