Object 0x20a0: auxiliary position actual value, Object 0x20a0: auxiliary position actual value -14, 0x20a0 – ElmoMC CANopen DS 301 Implementation Guide User Manual

Page 91

Advertising
background image

Default value

No

After the final character of each S-record line, the host must send the character 0x0A to
indicate end-of-line. The next S-record can be sent immediately after 0xA.

Example:
First, the host initiates an SDO segmented sequence:

Byte

0

Byte

4

Byte

7

20 0x90 0x20 0x00 0x00 0x00 0x00 0x00

After the reply from the drive, the host transmits:

Byte

0

Byte

4

Byte

7

00 “S” “3” “6” “A” “3” “9” “1”

The end-of-line format and the beginning of a new S-record line:

Byte

0

Byte

4

Byte

7

10 “8” “5” 0x0A

“S” “6” “0” “B”

Note: This object was removed from the EDS file to enable successful automatic

EDS file testing.

Object 0x20A0: Auxiliary position actual value

This object returns the actual position of the auxiliary axis (PY).

ƒ

Object description:

Index 20A0h

Name Auxiliary

position

Object code

VAR

Data type

SIGNED32

Category Optional

ƒ

Entry description:

Access Read

only

PDO mapping

Yes

Value range

-10

9

…10

9

Default value

No

CANopen DS 301 Implementation Guide

Manufacturer-specific Objects

MAN-CAN301IG (Ver. 2.1)

13-14