Specifications 101

Non-Volatile Configuration

A copy of the module configuration is
retained in non-volatile memory from where
it is loaded upon power up*.

*The configuration stored in non-volatile

memory can be deleted only by a module-reset
command sent via the serial interface, using
the Serial Configuration Utility, or via
DeviceNet from any compliant software
application.

Accuracy (minimum)

±1% of full scale range for the channel
±1% of alarm setpoint for speed

Power

Module

Consumption

Heat Production

Transducer

+21.6 to +26.4V dc

Maximum: 300 mA
Typical: 175 mA

Maximum: 7 Watts (24 BTU/hr)
Typical: 4 Watts (14 BTU/hr)

Isolated 24V dc, user configurable with
wiring

Environmental

Operating Temperature

Storage Temperature

Relative Humidity

Conformal Coating

-20 to +65°C (-4 to +149°F)

-40 to +85°C (-40 to +185°F)

95% non-condensing

All printed circuit boards are conformally
coated in accordance with IPC-A-610C.

Physical

Dimensions

Terminal Screw Torque

Height: 3.8 in (97 mm)
Width: 3.7 in (94 mm)
Depth: 3.7 in (94 mm)

7 pound-inches (0.6 Nm)