DeviceNet Objects 165

Services

12

Get

Data Format

USINT

The format of the
spectrum data.

0 = Complex data
For instances 3 and 4, this value
equals 1, which is Real data

13

Get

Average Type

USINT

The type of averaging
performed.

0 = Asynchronous (spectrum)
1 = Synchronous (waveform)

Determined by the
Synchronous attribute of the
Channel Object.

When set to Asynchronous,
consecutive spectrum
measurements are averaged
together to produce the
Spectrum data.

When set to asynchronous,
synchronized waveforms are
averaged together to produce
the Waveform data, and the
Spectrum data is produced
from the averaged waveform. A
trigger source from a
tachometer, for example, is
required to obtain the
synchronized waveforms.

14

Get/Set

Number of
Averages

UINT

The number of individual
data sets to be
incorporated into the
average calculation.

0 = Invalid
1 = No averaging
> 1 = Averaging

Table C.52 Spectrum Waveform Measurement Object Instance Attributes

Attr ID

Access
Rule

Name Data

Type

Description

Semantics

Table C.53 Spectrum Waveform Measurement Object Services

Service
Code

Class/Instance Usage

Name

Description

0E

h

Instance

Get_Attribute_Single

Returns a single attribute.

10

h

Instance

Set_Attribute_Single

Sets a single attribute.

1

4B

h

Instance

Get_Spectrum_Chunk

Upload a portion of the
current Spectrum data.

Advertising