Services, Vector measurement object (class id 329h), Class attributes – Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual

Page 184: Vector measurement object (class id 329

Advertising
background image

Publication GMSI10-UM013D-EN-P - May 2010

174 DeviceNet Objects

Services

1

Attributes can only be set while the device is in Program Mode. See the description of the Device Mode Object
for more information.

Vector Measurement
Object
(Class ID 329

H

)

The Vector Measurement Object models the measurement of the amplitude
and phase of the input signal at a specific multiple of the machine speed.

Class Attributes

The Vector Measurement Object provides no class attributes.

7

Get/Set

Fault High

REAL

The maximum expected
DC Bias voltage from the
transducer in volts.

Volts

8

Get/Set

Fault Low

REAL

The minimum expected
DC Bias voltage from the
transducer in volts.

Volts

9

Get/Set

Power Type

USINT

Indicates the type of
power supplied to the
transducer.

0 = No power supplied
1 = Constant current (IEPE
accelerometer)
2 = Constant voltage (IRD 941)

13

Get/Set

DC Bias Time
Constant

REAL

The time constant value
used for exponential
averaging of the DC Bias
value (a low pass
filter/output smoothing
filter).

Seconds

Table C.62 Transducer Object Instance Attributes

Attr ID

Access
Rule

Name Data

Type

Description

Semantics

Table C.63 Transducer Object Services

Service
Code

Class/Instance Usage

Name

Description

0E

h

Instance

Get_Attribute_Single

Returns a single attribute.

10

h

Instance

Set_Attribute_Single

Sets a single attribute.

1